Page 12 - B+L Canada Storz Catalogue
P. 12
Calipers, Gauges & Rulers
E2421 Mendez Degree Gauge
• Used to determine incision angles.
• Calibrated every 10° from 0° to 180°.
• Inner dimensions: 12.0mm, 0.75 inches. • Round knurled handle.
• Stainless, dull finish.
• Overall Length: 113.0mm, 4.5 inches.
E2432 Nichamin Double-Ended LRI/Toric Gauge
• This double-ended instrument has a modified Mendez Gauge on one end that is designed to align with preoperative limbal reference markings in order to identify the steep meridian over which the LRIs or Toric IOL is to be centred.
• The opposite end of the instrument is designed to permit arc length determination.
• The zero point is placed over the steep meridian that is to be incised, and the appropriate arc length is then delineated on the surface of this second gauge.
• Overall Length: 145.0mm, 5.7 inches.
E9036 Wallace Capsulorhexis Gauge
• 6.0mm corneal marker provides an excellent reference to gauge the diameter of the anterior capsular opening during capsulorhexis.
• Creating a tear just inside the circular mark on the cornea provides a sub 6.0mm capsulorhexis which is ideal for the latest IOL technology.
• Overall Length: 81.0mm, 3.2 inches.
ET2425 Wallace Mendez Degree Gauge
• 10° interval marks. Designed for surgeons familiar with use of a standard phoropter.
• Measures 0° to 180° twice in 10° increments.
• Round handle.
• Inner ring diameter: 12.0mm.
• Outer ring diameter: 16.0mm.
• Overall Length: 105.0mm, 4.1 inches.
4 bauschsurgical.ca | 1-800-387-3284
Gauges